Model No.︰-
Brand Name︰KharkovEnergoPribor Ltd.
Country of Origin︰Ukraine
Unit Price︰-
Minimum Order︰-
CBC-M-series systems are designed for high-voltage testing of electrical protective equipment and insulated hand tools. Withstand tests are carried out with AC voltage (CBC-50M: AC ≤ 50 kV; CBC-100M: AC ≤ 100 kV) at industrial frequency (f = 50 Hz).
VERSATILITY
CBC-M-series systems include a variety of holders and adaptors allowing to test a wide range of the objects:
✓ rubber insulating gloves and dielectric safety boots;
✓ hand tools with electrical insulation;
✓ voltage detectors and indicators;
✓ discharge rods;
✓ insulating mats.
EASY AND CONVENIENT CONTROL
Four pre-set of output voltage levels.
Test duration is set and monitored via a built-in timer.
Leakage current is displayed throughout the entire test cycle.
Upon detecting a breakdown, the system indicates the specific glove the breakdown has occurred in and automatically terminates the test.
SPLIT-UNIT DESIGN
The system is composed of a control unit, test bath and a high-voltage unit (two for CBC-100M). The test procedure is controlled from the control unit, which may be positioned at a safe distance away from high-voltage source and the test bath, ensuring operator safety.
SAFETY
CBC-M-series systems include the following operational safety measures:
✓ Overcurrent protection.
✓ Automatic short-circuiter on the high-voltage unit.
✓ Protective earthing.
✓ Fuses.
✓ Sulphur hexafluoride gas pressure monitoring in the high-voltage unit (units).
✓ Emergency stop button.